Experimental study of autonomous systems of liquid cooling of the piston compressor
DOI:
https://doi.org/10.25206/1813-8225-2018-161-33-38Keywords:
piston compressor, cooling, autonomous operation, mobile compressor stations, experimentAbstract
The article describes experimental studies to determine the effect of the two variants of the hydraulic autonomous cooling
system on the temperature of the cylinder-piston group using pressure fluctuations in the suction cavity of the piston low-flow
compressor. A comparison with a conventional external cooling system using atmospheric air flow is presented. It is shown that the use of automatic control of air flow resistance in the suction has a positive effect on reducing the temperature of the cylinder.
Downloads
Published
How to Cite
Issue
Section
License